Ghost artifact removal in EPI using projection in hybrid-space()
Share:

Journal of Southeast University (English Edition)[ISSN:1003-7985/CN:32-1325/N]

Volumn:
21
Issue:
2005 4
Page:
436-439
Research Field:
Computer Science and Engineering
Publishing date:
2005-12-30

Info

Title:
Ghost artifact removal in EPI using projection in hybrid-space
Author(s):
Gui Zhiguo1 2 Shu Huazhong1 Wang Shijie1 Luo Limin1
1 Laboratory of Image Science and Technology, Southeast University, Nanjing 210096, China
2 Department of Information Engineering, North University of China, Taiyuan 030051, China
Keywords:
echo planar imaging ghost artifact magnetic resonance imaging projection of phase
PACS:
TP391.1;R445-39
DOI:
10.3969/j.issn.1003-7985.2005.04.012
Abstract:
Ghost artifacts occur in magnetic resonance imaging(MRI)reconstruction because odd and even echoes have different phase offsets.A method based on the projection in hybrid-space is described to remove ghost artifacts.First, the projection of the even and odd lines along phase-encoding direction in hybrid-space was used to estimate the phase difference between odd and even echoes.Secondly, we fit the phase difference and used it to correct the phase of even or odd echoes.Finally, the corrected image was obtained by performing the inverse Fourier transform along phase-encoding direction in hybrid-space.The experimental results show that linear and nonlinear differences can be corrected and the intensity of ghost artifacts is significantly reduced.The effectiveness of the proposed method is demonstrated in ghost artifact removal.

References:

[1] Grieve S M, Blamire A M, Styles P.Elimination of Nyquist ghosting caused by read-out to phase-encoded gradient cross-terms in EPI [J].Magn Reson Med, 2002, 47(2):337-343.
[2] Bruder H, Fischer H, Reinfelder H E, et al.Image reconstruction for echo planar imaging with nonequidistant k-space sampling [J].Magn Reson Med, 1992, 23(2):311-323.
[3] Hennel F.Image-based reduction of artifacts in multishot echo-planar imaging [J].J Magn Reson, 1998, 134(2):206-213.
[4] Buonocore M H, Zhu D C.Image-based ghost correction for interleaved EPI [J].Magn Reson Med, 2001, 45(1):96-108.
[5] Buonocore M H, Gao L.Ghost artifact reduction for echo planar imaging using image phase correction [J].Magn Reson Med, 1997, 38(1):89-100.
[6] Foxall D L, Harvey P R, Huang J.Rapid iterative reconstruction for echo planar imaging [J].Magn Reson Med, 1999, 42(3):541-547.
[7] McGee K P, Manduca A, Felmlee J P, et al.Image metric-based correction(autocorrection)of motion effects:analysis of image metrics [J].J Magn Reson Imaging, 2000, 11(2):174-181.
[8] Manduca A, McGee K P, Welch E B, et al.Autocorrection in MR imaging:adaptive motion correction without navigator echoes [J].Radiology, 2000, 215(3):904-909.
[9] Atkinson D, Hill D L, Stoyle P N, et al.Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion [J].IEEE Trans Med Imaging, 1997, 16(12):903-910.
[10] McGee K P, Felmlee J P, Manduca A, et al.Rapid autocorrection using prescan navigator echoes [J].Magn Reson Med, 2000, 43(4):583-588.
[11] Hu X P, Le T H.Artifact reduction in EPI with phase-encoded reference scan [J].Magn Reson Med, 1996, 36(1):166-171.
[12] Lee K J, Barber D C, Paley M N, et al.Image-based EPI ghost correction using an algorithm based on projection onto convex sets(POCS)[J].Magn Reson Med, 2002, 47(4):812-817.
[13] Lee K J, Papadakis N G, Barber D C, et al.A method of generalized projections(MGP)ghost correction algorithm for interleaved EPI [J].IEEE Trans Med Imaging, 2003, 23(7):839-848.

Memo

Memo:
Biographies: Gui Zhiguo(1972—), male, doctor;Shu Huazhong(corresponding author), male, professor, shu.list@seu.edu.cn.
Last Update: 2005-12-20