|Table of Contents|

[1] Qian Shunzhi,. Fracture suppression at steel/concrete connection zones by ECC [J]. Journal of Southeast University (English Edition), 2012, 28 (2): 190-194. [doi:10.3969/j.issn.1003-7985.2012.02.011]
Copy

Fracture suppression at steel/concrete connection zones by ECC()
Share:

Journal of Southeast University (English Edition)[ISSN:1003-7985/CN:32-1325/N]

Volumn:
28
Issue:
2012 2
Page:
190-194
Research Field:
Traffic and Transportation Engineering
Publishing date:
2012-06-30

Info

Title:
Fracture suppression at steel/concrete connection zones by ECC
Author(s):
Qian Shunzhi
School of Transportation, Southeast University, Nanjing 210096, China
Keywords:
engineered cementitious composite(ECC) material ductility steel/concrete interaction zones fracture suppression
PACS:
U444
DOI:
10.3969/j.issn.1003-7985.2012.02.011
Abstract:
In order to avoid brittle fracture failure, a ductile engineered cementitious composite(ECC)was attempted in steel/concrete connection zones to replace normal concrete. The influence of the ECC material ductility on connection failure modes and structural performance was investigated via the pushout test of stud/ECC connection, the pullout test of two-dimensional anchor bolt/ECC connection and the finite element modeling(FEM). The experimental results suggest that the micromechanically designed ECC with a tensile ductility 300 times that of normal concrete switches the brittle fracture failure mode to a ductile one in steel connection zones. This modification in material behavior leads to higher load carrying capacity and structural ductility, which is also confirmed in FEM investigation. The enhancement in structural response through material ductility engineering is expected to be applicable to a wide range of engineering structures where steel and concrete come into contact.

References:

[1] Elfgren L. Round robin analysis and tests of anchor bolts in concrete structures. TC 90-FMA [R]. Bagneux: RILEM Publication, 1998.
[2] Architectural Institute of Japan and Japan Society of Civil Engineers. Records of the 1995 great Hanshin-Awaji earthquake disaster [R]. AIJ/JSCE, 1995.(in Japanese)
[3] Sheikh T M, Deierlein G G. Beam-column moment connections for composite frames: Part 1[J]. Journal of Structural Engineering, 1989, 115(11): 2858-2876.
[4] Parra-Montesinos G, Wight J K. Seismic response of exterior RC column-to-steel beam connections[J]. Journal of Structural Engineering, 2000, 126(10): 1113-1121.
[5] Breen J E, Burdet O, Roberts C, et al. Anchorage zone reinforcement for post-tensioned concrete girders. NCHRP 356[R].Washington: National Cooperative Highway Research Program, 1994.
[6] Li V C. From micromechanics to structural engineering—the design of cementitious composites for civil engineering applications[J]. JSCE Journal of Structural Engineering and Earthquake Engineering, 1993, 10(2): 37-48.
[7] Li V C, Kanda T. Engineered cementitious composites for structural applications[J]. Journal of Materials in Civil Engineering, 1998, 10(2): 66-69.
[8] Li V C, Wang S, Wu C. Tensile strain-hardening behavior of PVA-ECC[J]. ACI Materials Journal, 2001, 98(6):483-492.
[9] Li V C, Mishra D K, Naaman A E, et al. On the shear behavior of engineered cementitious composites[J]. Journal of Advanced Cement Based Materials, 1994, 1(3):142-149.
[10] Kanda T, Watanabe W, Li V C. Application of pseudo strain hardening cementitious composites to shear resistant structural elements[C]//Proceedings FRAMCOS-3. Freiburg, Germany: AEDIFICATIO Publishers, 1998:1477-1490.
[11] Kesner K E, Billington S L. Experimental response of precast infill panels made with DFRCC[C]//Proceedings of JCI Workshop on DFRCC. Takayama, Japan, 2002:289-298.
[12] Fukuyama H, Matsuzaki Y, Nakano K, et al. Structural performance of beam elements with PVA-ECC[C]//Proceedings of High Performance Fiber Reinforced Cement Composites 3(HPFRCC 3). Ann Arbor, MI, USA, 1999:531-542.
[13] Ollgaard J G, Slutter R G, Fisher J W. Shear strength of stud connectors in lightweight and normal-weight concrete[J]. AISC Engineering Journal, 1971, 8(2):55-64.
[14] Qian S, Li V C. Headed anchor/engineered cementitious composites(ECC)pullout behavior[J]. Journal of Advanced Concrete Technology, 2011, 9(3): 339-351.

Memo

Memo:
Biography: Qian Shunzhi(1976—), male, doctor, professor, sqian@seu.edu.cn.
Foundation items: The National Natural Science Foundation of China(No.51008071), the Natural Science Foundation fo Jiangsu Province(No.BK2010413), Teaching & Research Excellence Grant for Young Faculty Members at Southeast University, the US National Science Foundation(No.CMS-0223971, CMS-0329416).
Citation: Qian Shunzhi.Fracture suppression at steel/concrete connection zones by ECC[J].Journal of Southeast University(English Edition), 2012, 28(2):190-194.[doi:10.3969/j.issn.1003-7985.2012.02.011]
Last Update: 2012-06-20