|Table of Contents|

[1] Xu Wei, Liang Shuting,. Experimental study on the seismic performanceof staggered slab-column joints [J]. Journal of Southeast University (English Edition), 2021, 37 (4): 408-412. [doi:10.3969/j.issn.1003-7985.2021.04.010]
Copy

Experimental study on the seismic performanceof staggered slab-column joints()
错层板柱节点抗震性能试验研究
Share:

Journal of Southeast University (English Edition)[ISSN:1003-7985/CN:32-1325/N]

Volumn:
37
Issue:
2021 4
Page:
408-412
Research Field:
Civil Engineering
Publishing date:
2021-12-20

Info

Title:
Experimental study on the seismic performanceof staggered slab-column joints
错层板柱节点抗震性能试验研究
Author(s):
Xu Wei1 Liang Shuting2
1 Architects & Engineers Co., Ltd., Southeast University, Nanjing 210096, China
2 School of Civil Engineering, Southeast University, Nanjing 210096, China
许巍1 梁书亭2
1东南大学建筑设计研究院有限公司, 南京210096; 2东南大学土木工程学院, 南京210096
Keywords:
staggered floor structure slab-column joints boundary beam seismic performance low cyclic loading
错层结构 板柱节点 边梁 抗震性能 低周反复加载
PACS:
TU375.4;TU317.1
DOI:
10.3969/j.issn.1003-7985.2021.04.010
Abstract:
The low-cycle loading test of two staggered slab-column-boundary beam joints was carried out to study their seismic performance. The crack development, load-displacement relationship, displacement ductility, and energy dissipation performance of the staggered slab-column joints(SSCJ)were studied. Experimental results reveal that both specimens present short-column brittle shear failure. Furthermore, an obvious hysteretic curve pinching phenomenon occurred. Thus, it can be concluded that the seismic performance of the joints is insufficient. These results suggest that the anchorage of the longitudinal reinforcement of the slab in the joint’s core area should be improved, and attention should be paid to the short-column stirrup configuration of the SSCJ. These results can provide a research basis for the design of such joints in future applications.
通过对2个错层板柱节点试件进行低周往复加载试验, 研究了错层板柱结构错层部位节点的力学性能.分析了错层板柱节点在低周反复荷载下的荷载-位移曲线、节点的延性、耗能能力等性能, 明确了错层板柱节点的工作机理及破坏形式.试验结果表明, 2个错层板柱节点试验构件均呈现典型的短柱脆性剪切破坏, 节点的滞回曲线捏拢现象明显, 耗能能力较弱, 可以看出错层板柱结构的节点抗震能力弱于一般框架结构.根据对试验现象的分析, 建议错层板柱节点中板纵筋应在节点核心区加强锚固, 并且在节点设计时需重点关注错层板柱节点短柱箍筋配置.试验结果可对错层板柱结构节点设计提供研究基础.

References:

[1] Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Code for seismic design of building: GB 50011—2010 [S]. Beijing:China Architecture & Building Press, 2010.
[2] Gasparini D A. Contributions of C.A.P. Turner to development of reinforced concrete flat slabs 1905—1909[J].Journal of Structural Engineering, 2002, 128(10): 1243-1252. DOI:10.1061/(asce)0733-9445(2002)128: 10(1243).
[3] Walker P R, Regan P E. Corner column-slab connections in concrete flat plates[J].Journal of Structural Engineering, 1987, 113(4): 704-720. DOI:10.1061/(asce)0733-9445(1987)113: 4(704).
[4] Lu X L, Ma Y C, Yang Z. Analysis of connections of slab to edge column under shear and unbalanced moment[J]. Journal of Tongji University, 1998, 26(8): 357-360.(in Chinese)
[5] Han S W, Park Y M, Kee S H. Stiffness reduction factor for flat slab structures under lateral loads[J].Journal of Structural Engineering, 2009, 135(6): 743-750. DOI:10.1061/(asce)st.1943-541x.0000001.
[6] Wu Q, Cheng W R. Study of calculating width of equivalent beam for slab-column structure subjected to horizontal forces[J]. Industrial Construction, 2004, 34(3): 77-79. DOI:10.3321/j.issn:1000-8993.2004.03.024. (in Chinese)
[7] Xu Z G, Huang X K, Gao J, et al. A seismic performance analysis on a shear-wall high-rise structure with staggered floors in high earthquake intensity regions[J]. Building Structure, 2012, 42(4): 69-74. DOI:10.19701/j.jzjg.2012.04.011. (in Chinese)
[8] Mao R P. Split-level building damaged in Wenchuan earthquake analysis[J]. Engineering Mechanics, 2010, 27(S1): 118-121.(in Chinese)
[9] Long J T, Chen Y, Wang H, et al. Seismic performance analysis of staggered floors in frame structures[J]. Structural Engineers, 2018, 34(5): 58-65. DOI:10.15935/j.cnki.jggcs.2018.05.009. (in Chinese)
[10] Wang Z J, Han F X. Shearing force analysis of split-level region for a split-level structure with uniform mass distribution under earthquake[J]. Journal of Vibration and Shock, 2011, 30(7): 91-95. DOI:10.13465/j.cnki.jvs.2011.07.049. (in Chinese)
[11] Zhou J. Research on staggered flat plate structure connections[D].Nanjing: Southeast University, 2006.(in Chinese)
[12] Wang J. Research on aseismic behavior of staggered flat plate structure[D]. Nanjing: Southeast University, 2008.(in Chinese)
[13] Park R. State of the art report ductility evaluation from laboratory and analytical testing [C]// Proceedings of Ninth World Conference on Earthquake Engineering. Tokyo, Japan, 1988: 605-616.

Memo

Memo:
Biography: Xu Wei(1975—), male, doctor, engineer, 101008890@seu.edu.cn.
Foundation item: The National Natural Science Foundation of China(No. 59878013).
Citation: Xu Wei, Liang Shuting.Experimental study on the seismic performance of staggered slab-column joints[J].Journal of Southeast University(English Edition), 2021, 37(4):408-412.DOI:10.3969/j.issn.1003-7985.2021.04.010.
Last Update: 2021-12-20