[1] Lee W F Z, Karlby H. A study of viscosity effect and its compensation on turbine-type flowmeters[J]. Journal of Basic Engineering, 1960, 82(3): 717-725. DOI:10.1115/1.3662720.
[2] Xu Y. Calculation of the flow around turbine flowmeter blades[J].Flow Measurement and Instrumentation, 1992, 3(1): 25-35. DOI:10.1016/0955-5986(92)90013-U.
[3] Nam K H, Park J H, Kim H J. Performance test of turbine flowmeter according to temperature variation[J].The KSFM Journal of Fluid Machinery, 2017, 20(2): 47-52. DOI:10.5293/kfma.2017.20.2.047.
[4] Zhang G F, Wang L H, Zhu Y J, et al. Turbine flowmeter response analysis based on PIV measurement[J]. Chinese Journal of Scientific Instrument, 2013, 34(10): 2381-2387. DOI:10.19650/j.cnki.cjsi.2013.10.032. (in Chinese)
[5] Sun L J, Zhou Z Y, Zhang T. Quantitative optimization method for rotor geometric parameters of liquid turbine flow sensor[J]. Chinese Journal of Scientific Instrument, 2007, 28(3): 493-498. DOI:10.19650/j.cnki.cjsi.2007.03.021. (in Chinese)
[6] Lee B, Cheesewright R, Clark C. The dynamic response of small turbine flowmeters in liquid flows[J]. Flow Measurement and Instrumentation, 2004, 15(5/6): 239-248. DOI:10.1016/j.flowmeasinst.2004.07.002.
[7] Tonkonogij J, Pedi0;9A;ius A, Stankevicˇius A. The new semi-experimental method for simulation of turbine flow meters rotation in the transitional flow[J]. Proceedings of World Academy of Science Engineering & Technology, 2008: 208-212.
[8] D0;9E;emic’Z, 0;160;irok B, Bizjan B. Turbine flowmeter response to transitional flow regimes[J]. Flow Measurement and Instrumentation, 2018, 59: 18-22. DOI:10.1016/j.flowmeasinst.2017.11.006.
[9] López-González L M, Sala J M, González-Bustamante J A, et al. Modelling and simulation of the dynamic performance of a natural-gas turbine flowmeter[J].Applied Energy, 2006, 83(11): 1222-1234. DOI:10.1016/j.apenergy.2005.12.002.
[10] Zheng D H, He X, Che D F. CFD simulations of hydrodynamic characteristics in a gas-liquid vertical upward slug flow[J].International Journal of Heat and Mass Transfer, 2007, 50(21/22): 4151-4165. DOI:10.1016/j.ijheatmasstransfer.2007.02.041.
[11] Wang Z, Zhang T. Computational study of the tangential type turbine flowmeter[J].Flow Measurement and Instrumentation, 2008, 19(5): 233-239. DOI:10.1016/j.flowmeasinst.2007.11.003.
[12] Guo S N, Sun L J, Zhang T, et al. Analysis of viscosity effect on turbine flowmeter performance based on experiments and CFD simulations[J].Flow Measurement and Instrumentation, 2013, 34: 42-52. DOI:10.1016/j.flowmeasinst.2013.07.016.
[13] Sun H J, Feng Y, Wang B. Numerical simulation and optimal design of front diversion body in gas turbine flowmeter[J]. Journal of Electronic Measurement and Instrumentation, 2016, 30(4): 550-557. DOI:10.13382/j.jemi.2016.04.007. (in Chinese)
[14] Wu D Z, Chen T, Sun Y B, et al. Study on numerical methods for transient flow induced by speed-changing impeller of fluid machinery[J].Journal of Mechanical Science and Technology, 2013, 27(6): 1649-1654. DOI:10.1007/s12206-013-0412-4.
[15] General Administration of Quality Supervision. Verification regulation of turbine flowmeter: JJG 1037—2008 [S]. Beijing: Inspection and Quarantine of the People’s Republic of China, 2008.(in Chinese)
[16] Guo S N, Yang Z H, Wang F, et al. Optimal design of wide viscosity range turbine flow sensor based on flow field analysis[J].Flow Measurement and Instrumentation, 2021, 79: 101909. DOI:10.1016/j.flowmeasinst.2021.101909.
[17] Zhao J L, Sun L J, Zhang T, et al. Experiment and numerical simulation study on the viscosity impact of turbine flowmeter’s performance[J].Advanced Materials Research, 2011, 301/302/303: 1283-1288. DOI:10.4028/www.scientific.net/amr.301-303.1283.
[18] Saboohi Z, Sorkhkhah S, Shakeri H. Developing a model for prediction of helical turbine flowmeter performance using CFD[J]. Flow Measurement and Instrumentation, 2015, 42: 47-57. DOI:10.1016/j.flowmeasinst.2014.12.009.
[19] Wang X. Research on turbine flowmeter for small flow viscous liquid [D]. Lanzhou: Lanzhou University of Technology, 2019.(in Chinese)